Alaxala AX2400S series Guia de Resolução de Problemas Página 252

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 251
5. Obtaining Failure Information
182
2. In the active BCU, execute the dump nif command for all the ports that have failed.
Example:
The following procedure shows an example in which communication fails on port number 1
of NIF number 1 when the BSUs are installed on the BSU numbers 1 and 2.
1. Log in to the active BCU, and then execute the
dump command.
> dump bsu 1
Dump command accept.
>
11/01 17:43:42 E3 BSU BSU:1 25070700 1681:000000000000 BSU online dump
command executed.
2. After the above log information is displayed, execute the following dump command.
> dump bsu 2
Dump command accept.
>
11/01 18:10:42 E3 BSU BSU:2 25070700 1681:000000000000 BSU online dump
command executed.
3. After the above log information is displayed, execute the following dump command.
> dump nif 1
Dump command accept.
>
11/01 18:15:42 E3 NIF NIF:1 25000700 1240:000000000000 NIF online dump
command executed.
Vista de página 251
1 2 ... 247 248 249 250 251 252 253 254 255 256 257 ... 304 305

Comentários a estes Manuais

Sem comentários